Search Page
Save citations to file
Email citations
Send citations to clipboard
Add to Collections
Add to My Bibliography
Create a file for external citation management software
Your saved search
Your RSS Feed
Filters
Results by year
Table representation of search results timeline featuring number of search results per year.
Year | Number of Results |
---|---|
2008 | 1 |
2013 | 1 |
2023 | 1 |
2024 | 0 |
Search Results
3 results
Results by year
Filters applied: . Clear all
Page 1
Free vibration analysis of Timoshenko pipes with fixed boundary conditions conveying high velocity fluid.
Heliyon. 2023 Mar 22;9(4):e14716. doi: 10.1016/j.heliyon.2023.e14716. eCollection 2023 Apr.
Heliyon. 2023.
PMID: 37009242
Free PMC article.
Sever vibration will be induced due to the high flow velocity in the pipe. When the flow velocity exceeds the critical value, the static equilibrium configuration of the pipe loses its stability, and the vibration properties change accordingly. ...The effects of sup …
Sever vibration will be induced due to the high flow velocity in the pipe. When the flow velocity exceeds the critical value, the sta …
PIV measurements of the flow field just downstream of an oscillating collapsible tube.
Bertram CD, Truong NK, Hall SD.
Bertram CD, et al.
J Biomech Eng. 2008 Dec;130(6):061011. doi: 10.1115/1.2985071.
J Biomech Eng. 2008.
PMID: 19045540
The rapid deceleration of flow at maximal collapse caused the jets momentarily to merge about one diameter into the downstream pipe, and strengthened and enlarged the existing retrograde flow lateral to each jet. ...The minor-axis flow fields showed that the between …
The rapid deceleration of flow at maximal collapse caused the jets momentarily to merge about one diameter into the downstream pip …
Item in Clipboard
A simple and flexible field-tested device for housing water monitoring sensors at point discharges.
Exner-Kittridge M, Niederreiter R, Eder A, Zessner M.
Exner-Kittridge M, et al.
Water Sci Technol. 2013;67(5):1026-33. doi: 10.2166/wst.2013.655.
Water Sci Technol. 2013.
PMID: 23416594
The WME ensures a minimum internal water level and this ensures that the internal monitoring equipment remains submerged even when there is no flow into the enclosure. The limited diameter of the inflow pipe and water volume in the WME buffers the flow velocity from …
The WME ensures a minimum internal water level and this ensures that the internal monitoring equipment remains submerged even when there is …
Item in Clipboard
Cite
Cite