Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2008 1
2013 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

3 results

Results by year

Filters applied: . Clear all
Page 1
Free vibration analysis of Timoshenko pipes with fixed boundary conditions conveying high velocity fluid.
Tan X, Tang YQ. Tan X, et al. Heliyon. 2023 Mar 22;9(4):e14716. doi: 10.1016/j.heliyon.2023.e14716. eCollection 2023 Apr. Heliyon. 2023. PMID: 37009242 Free PMC article.
Sever vibration will be induced due to the high flow velocity in the pipe. When the flow velocity exceeds the critical value, the static equilibrium configuration of the pipe loses its stability, and the vibration properties change accordingly. ...The effects of sup …
Sever vibration will be induced due to the high flow velocity in the pipe. When the flow velocity exceeds the critical value, the sta …
PIV measurements of the flow field just downstream of an oscillating collapsible tube.
Bertram CD, Truong NK, Hall SD. Bertram CD, et al. J Biomech Eng. 2008 Dec;130(6):061011. doi: 10.1115/1.2985071. J Biomech Eng. 2008. PMID: 19045540
The rapid deceleration of flow at maximal collapse caused the jets momentarily to merge about one diameter into the downstream pipe, and strengthened and enlarged the existing retrograde flow lateral to each jet. ...The minor-axis flow fields showed that the between …
The rapid deceleration of flow at maximal collapse caused the jets momentarily to merge about one diameter into the downstream pip
A simple and flexible field-tested device for housing water monitoring sensors at point discharges.
Exner-Kittridge M, Niederreiter R, Eder A, Zessner M. Exner-Kittridge M, et al. Water Sci Technol. 2013;67(5):1026-33. doi: 10.2166/wst.2013.655. Water Sci Technol. 2013. PMID: 23416594
The WME ensures a minimum internal water level and this ensures that the internal monitoring equipment remains submerged even when there is no flow into the enclosure. The limited diameter of the inflow pipe and water volume in the WME buffers the flow velocity from …
The WME ensures a minimum internal water level and this ensures that the internal monitoring equipment remains submerged even when there is …